Specifications
- Slave ID consumption: 2
- LED indicator: Power and Link
- Power supply required: 10~30V DC
- 16-CH single-ended or 8-CH differential analog inputs (Jumper
Select)
- Resolution: 16 bits
- Unit Coversion : Thermocouple, mV, V or mA
- Input range programmable 6 levels (Bipolar) : ±2.5V,
±1V, ±500mV, ±100mV, ±50mV, ±15mV,
±20mA
- Input range programmable 6 levels (Unipolar) : ±2.5V,±1V,
±500mV,±100mV, ±50mV, ±15mV, ±20mA
- Input range (Thermocouple Type, both Unipolar and Bipolar) :
J, K, T, E, R, S, B, N, C
J: 0°C~760°C
T: -100°C~400°C
R: 500°C~1750°C
B: 500°C~1800°C
C: 0°C~2320°C
K: 0°C~1370°C
E: 0°C~1000°C
S: 500°C~1750°C
N: -270°C~1300°C
- Sampling Rate(all channels) : 100Hz
|